Keywords:  *
JGX-1595FXC Magnetic Isolation DC Solid State Relay series
JGX-1595FXC using in the hard environmental condition
JGX-1595FXC Magnetic Isolation DC Solid State Relay series
Brief introductiontop ↑
JGX-1595FXC Magnetic Isolation DC Solid State Relay series
DC OUTPUT:
1. Power field effect tube output.
2. Magnetic isolation is applied to protect control.
3. GJB1515A-2001.
JGX-1595FXC Magnetic Isolation DC Solid State Relay series
specificationtop ↑
JGX-1595FXC Magnetic Isolation DC Solid State Relay series
No.
Item
Data
1
Rated out-put Current
80A
2
Over Load
150A
3
Out-put Voltage drop
0.5VDC
4
Out-put Current leakage
1000uA
5
Turn on Time
100us
6
Turn off Time
1000us
7
Insulation Resistance
1000 MO
8
Dielectric Withstanding Voltage
1000Vr.m.s.
9
Weight
125g
JGX-1595FXC Magnetic Isolation DC Solid State Relay series
how to ordertop ↑
JGX-1595FXC Magnetic Isolation DC Solid State Relay series
JGX-1595FXC / 010W-80- 6 
   1                   2     3.
1. Model
2. Part No.
3. terminal arrangement code
JGX-1595FXC Magnetic Isolation DC Solid State Relay series
Environmental Conditiontop ↑
JGX-1595FXC Magnetic Isolation DC Solid State Relay series
No.
Item
Data
1
Temperature range
-55~ +85°C
2
Stock Temperature
-55~ +100 ?
3
Shock
980m/ s2
4
Vibration
10~2000Hz, 294m/s2
JGX-1595FXC Magnetic Isolation DC Solid State Relay series
Main Technical Datatop ↑
JGX-1595FXC Magnetic Isolation DC Solid State Relay series
Part
No.
In-put Voltage
(VDC)

In-put Current

(mA)

Turn-off Voltage

(VDC)

Reverse Voltage

(VDC)

Out-put Voltage(VDC)

 
Instantaneous Voltage (VDC)
005-80-
3~7
=15
=1
7
80
100
010-80-
10~32
=15
=2
32
80
100
JGX-1595FXC Magnetic Isolation DC Solid State Relay series