Keywords:  *
SRB-RELAY
Microelectromagnetic Relay with PCB Mounting Form
Product solid picturetop ↑
SRB-RELAY
SRB-RELAY Relays Product solid picture
SRB-RELAY
Brief introductiontop ↑
SRB-RELAY
· Switching capacity available by 3A in spite of small size design for highdensity P.C. board mounting technique.
· Selection of plastic material for high temperature and better chemical solution performance.
· Sealed types available.
· Simple relay magnetic circuit to meet low cost of mass production.
SRB-RELAY
specificationtop ↑
SRB-RELAY
Contact form
1a, 1b, 1c
Rated load
3A-125VAC/28VDC,1A 240VAC/28VDC
Contact resistance
<=50m (ohm)
Electrical life
100,000
Mechanical life
10,000,000
Coil rated voltage
3-48VDC
Coil power
0.36W, 0.45W
Coil pick-up voltage
<=75%
Coil drop-out voltage
>=10%
Ambient temperature
-25 degrees Celsius to +70 degrees Celsius
Coil and contacts
750VAC/min
Contact and contacts
750VAC/min
Insulation resistance
>=100M (ohm)
Mounting form
PCB
Weight (g)
10
Outline dimensions (mm)
19.0 x 15.5 x 15.0
SRB-RELAY
Product Informationtop ↑
SRB-RELAY

SRB
XX VDC
C
L
C
Model of relay
Nominal coil voltage
Contact form
Coil sensitivity
Contact form
SRB
03,05,06,09,12,24VDC
S:Sealed type
L: 0.36W
A:1 form A
B:1 form B
F:Flux free type
D:0.45W
C:1 form C

 

SRB-RELAY
Outline Mounting Dimensionstop ↑
SRB-RELAY

DIMENSION(unit:mm)
DRILLING(unit:mm)
WIRING DIAGRAM
SRB-RELAY Relays Outline Mounting Dimensions

SRB-RELAY
Applicationstop ↑
SRB-RELAY
· Domestic appliance, office machine, audio, equipment, automobile, etc.

 

SRB-RELAY
Performancetop ↑
SRB-RELAY
Type
Item
SLC
Contact Resistance
100m?Max.
Operation Time
10msec Max.
Release Time
5msec Max.
Dielectric Strength Between coil & contact Between contacts
1000VAC 50/60HZ (1 minute)
500VAC 50/60 HZ (1 minute)
Surge Resistiveness
3000V (between coil & contact 1×40 usec)
Insulation Resistance
100 M?Min. (500VDC)
Max. ON/OFF Switching Mechanically
Electrically
300 operation/min
30 operation/min
Operating Ambient Temperature
-30? to +80?
(No water condensation and no water drop)
Operating Humidity
45 to 85% RH
Vibration
Endurance
Error Operation
10 to 55Hz Double Amplitude 1.5mm
10 to 55Hz Double Amplitude 1.5mm
Shock
Endurance
Error Operation
100G Min.
10G Min.
Life Expectancy Mechanically
Electrically
1×108operations. Min. (no load)
1×104 operations. Min (at rated coil voltage).
Weight
Abt. 10grs.
SRB-RELAY
Ratingtop ↑
SRB-RELAY
1A/240VAC 28VDC
3A/125VAC 28VDC
SRB-RELAY
Coil Data Charttop ↑
SRB-RELAY

Coil Sensitivity
Coil Voltage Code
Nominal
Voltage
(VDC)
Nominal
Current
(mA)
Coil Resistance
O(±10%)
Power Consumption
(W)
Pick-In voltage
(VDC)
Drop-out voltage
(VDC)
Max-Allowable Voltage
(VDC)
SRB
(High Sensitivity)
03
03
120
25
Abt.0.36W
75%Max.
5% Min.
120%
05
05
71.4
70
06
06
60
100
09
09
40
225
12
12
30
400
24
24
15
1600
48
48
7.5
6400
Standard Sensitivity
03
03
150
20
Abt.0.45W
75% Max.
5% Min.
110%
05
05
89.3
55
06
06
75
80
09
09
50
180
12
12
37.5
320
24
24
18.7
1280

 

SRB-RELAY
Contact Ratingtop ↑
SRB-RELAY
Type
Item
SRB
Contact Capacity Resistive Load (cosF=1)
1A 240VAC 28VDC
3A/125VAC 28VDC
Rated Carrying Current
1A
Max. Allowable Voltage
250VAC/110VDC
Max. Allowable Current
3A
Max. Allowable Power Force
360VAC/70W
Contact Material
Ag Alloy
SRB-RELAY
Reference Datatop ↑
SRB-RELAY

SRB-RELAY Relays Reference Data
SRB-RELAY Relays Reference Data
SRB-RELAY Relays Reference Data
SRB-RELAY Relays Reference Data

SRB-RELAY