SRD-RELAY |
Microelectromagnetic Relay Made with Superior Technique
|
|
|
Brief introduction | top ↑ |
SRD-RELAY·Switching capacity available by 10A in spite of small size design for highdensity P.C. board mounting technique. ·UL,CUL,TUV recognized. ·Selection of plastic material for high temperature and better chemical solution performance. ·Sealed types available. ·Simple relay magnetic circuit to meet low cost of mass production. | SRD-RELAY |
specification | top ↑ |
SRD-RELAYContact form | 1a, 1b, 1c | Rated load | 10A 250VAC/30VDC,10A 125VAC/28VDC,7A 240VAC/28VDC | Contact resistance | <=100m (ohm) | Electrical life | 100,000 | Mechanical life | 10,000,000 | Coil rated voltage | 3-48VDC | Coil power | 0.36W, 0.45W | Coil pick-up voltage | <=75% | Coil drop-out voltage | >=10% | Ambient temperature | -25 degrees Celsius to +70 degrees Celsius | Coil and contacts | 1500VAC/min | Contact and contacts | 1000VAC/min | Insulation resistance | >=100M (ohm) | Mounting form | PCB | Weight (g) | 10 | Outline dimensions (mm) | 19.0x 15.5 x 15.0 | SRD-RELAY |
Product Information | top ↑ |
SRD-RELAYSRD | XX VDC | S | L | C | Model of relay | Nominal coil voltage | Structure | Coil sensitivity | Contact form | SRD | 03,05,06,09,12,24,48VDC | S:Sealed type | L: 0.36W | A:1 form A | B:1 form B | F:Flux free type | D:0.45W | C:1 form C | SRD-RELAY |
Applications | top ↑ |
SRD-RELAY·Domestic appliance, office machine, audio, equipment, automobile, etc. ( Remote control TV receiver, monitor display, audio equipment high rushing current use application.) |
SRD-RELAY |
Performance | top ↑ |
SRD-RELAYType Item | SRD | Contact Resistance | 100m?Max. | Operation Time | 10msec Max. | Release Time | 5msec Max. | Dielectric Strength Between coil & contact Between contacts | 1500VAC 50/60HZ(1 minute) 1000VAC 50/60HZ(1 minute) | Insulation Resistance | 1000 M?Min. (500VDC) | Max. ON/OFF Switching Mechanically Electrically | 300 operation/min 30 operation/min | Ambient Temperature | -25? to +70? | Operating Humidity | 45 to 85% RH | Vibration Endurance Error Operation | 10 to 55Hz Double Amplitude 1.5mm 10 to 55Hz Double Amplitude 1.5mm | Shock Endurance Error Operation | 100G Min. 10G Min. | Life Expectancy Mechanically Electrically | 107 operations. Min. (no load) 105 operations. Min.(at rated coil voltage) | Weight | Abt. 10grs. | SRD-RELAY |
Rating | top ↑ |
SRD-RELAYCCC | FILE NUMBER:CH0052885-2000 | 7A/240VDC | CCC | FILE NUMBER:CH0036746-66 | 10A/250VDC | UL/CUL | FILE NUMBER:E167996 | 10A/125VAC 28VDC | TUV | FILE NUMBER:R9933789 | 10A/250VAC 30VDC | SRD-RELAY |
Coil Data Chart | top ↑ |
SRD-RELAYCoil Sensitivity | Coil Voltage Code | Nominal Voltage (VDC) | Nominal Current (mA) | Coil Resistance O(±10%) | Power Consumption (W) | Pick-In voltage (VDC) | Drop-out voltage (VDC) | Max-Allowable Voltage (VDC) | | 03 | 03 | 120 | 25 | Abt.0.36W | 75%Max. | 10% Min. | 120% | 05 | 05 | 71.4 | 70 | 06 | 06 | | 100 | 09 | 09 | 40 | 225 | 12 | 12 | 30 | 400 | 24 | 24 | 15 | 1600 | 48 | 48 | 7.5 | 6400 | SRD (Standard) | 03 | 03 | 150 | 20 | Abt.0.45W | 75% Max. | 10% Min. | 110% | 05 | 05 | 89.3 | 55 | 06 | 06 | 75 | 80 | 09 | 09 | 50 | 180 | 12 | 12 | 37.5 | 320 | | 24 | 18.7 | 1280 | 48 | 48 | 10 | 4500 | Abt.0.51W | SRD-RELAY |
Contact Rating | top ↑ |
SRD-RELAYType Item | SRD | FORM C | FORM A | Contact Capacity Resistive Load (cos?=1) | 7A 28VDC 10A 125VDC 7A 240VAC | 10A 28VDC 10A 240VAC | Inductive Load (cos?=0.4 L/R=7msec) | 3A 120VAC 3A 28VDC | 5A 120VAC 5A 28VDC | Max. Allowable Voltage | 250VAC/110VDC | 250VAC/110VDC | Max. Allowable Power Force | 800VAC/240W | 1200VA/300W | Contact Material | AgCdO | AgCdO | SRD-RELAY |
|