Keywords:  *
JQ-37FH Contactor seriesTotal > RELAYS > Special Relay > JQ-37FH Contactor series
JQ-37FH Contactor series
JQ-37FH Contactor using in the hard environmental condition
Brief introductiontop ↑
JQ-37FH Contactor series
JQ-37FH Contactor using in the hard environmental condition
JQ-37FH Contactor series
specificationtop ↑
JQ-37FH Contactor series
Coil power (W)
=7
Load Range of Contact Resistance
5~150A,
5~380Va.c.
Contact Resistance (mO)
Initial Value
=50
After Life Testing
=150
Insulation
Resistance
(MO)
Normal
=1000
Maximum Switching Power
57000VA
High Level Life
=100
Contact Load and Life
150A,380Va.c., 50Hz, 3F,10,000 operations
Dielectric Strength
Vr.m.s.
(50Hz)
Normal Pressure
1800
Low Pressure
400
Weight(g)
=1200
JQ-37FH Contactor series
how to ordertop ↑
JQ-37FH Contactor series
JQ-37FH  /  024  -  1
(1)      (2)     (3)
(1) Model No.
(2) Specification NO.
(3)Installation Type No.
JQ-37FH Contactor series
Environmental Conditiontop ↑
JQ-37FH Contactor series
Ambient Temperature Range (?)
-55~85?
Relative Humidity
98%(at 40?)
Low Pressure (kPa)
2.5
Vibration
98m/s2 , 10-500Hz
Shock Resistance(m/s2)
196
Acceleration(m/s2)
245
JQ-37FH Contactor series
Main Technical Datatop ↑
JQ-37FH Contactor series
No.
Coil voltage
25?
Temperature range
Rated
Max
Coil Resistance
(O)±10%
Working Voltage
(Max)
Sustaining Voltage
(Max)
Release Voltage
(Min)
Working Voltage
(Max)
Sustaining Voltage
(Max)
Release Voltage
(Min)
Holding
Startup
024
24
26.4
82.0
6.0
15.1
7.2
1.7
20.0
12.0
1.0
027
27
29.7
103.5
7.5
18.0
8.1
1.9
23.0
13.5
1.1
036
36
39.6
185.0
13.0
24.0
10.8
2.5
30.6
18.0
1.5
060
60
66.0
510.0
36.0
40.0
18.0
4.2
51.0
30.0
2.5
110
110
121.0
1725.0
125.0
73.3
33.0
7.7
93.5
55.0
4.6
220
220
242.0
6920.0
500.0
154.0
74.0
22.9
182.6
110.0
13.8
JQ-37FH Contactor series