Keywords:  *
JGX-5125 Hermetical AC & DC Solid State Relay series
JGX-5125 using in the hard environmental condition
Brief introductiontop ↑
JGX-5125 Hermetical AC & DC Solid State Relay series
DC OUTPUT:
1. Power field effect tube output.
2. Magnetic isolation is applied to protect control.
3. GJB1515A-2001.
JGX-5125 Hermetical AC & DC Solid State Relay series
specificationtop ↑
JGX-5125 Hermetical AC & DC Solid State Relay series
No.
Item
Data
1
Rated out-put Current
10A
2
Over Load
50A
3
Out-put Voltage
50VDC
4
Out-put Current leakage
10uA
5
Turn on Time
100us
6
Turn off Time
300us
7
Instantaneous Voltage
75VDC
8
Out-put Voltage drop
0.6VDC
9
Insulation Resistance
1000 MO
10
Dielectric Withstanding Voltage
1000Vr.m.s.
11
Leakage rate
1 x10-1 Pa.cm3 /s
12
Weight
80g
JGX-5125 Hermetical AC & DC Solid State Relay series
how to ordertop ↑
JGX-5125 Hermetical AC & DC Solid State Relay series
JGX-5125M  /  005W-50- 
     1                   2      
1. Model
2. Part No.
JGX-5125 Hermetical AC & DC Solid State Relay series
Environmental Conditiontop ↑
JGX-5125 Hermetical AC & DC Solid State Relay series
No.
Item
Data
1
Temperature range
-55~ +105°C
2
Stock Temperature
-55~ +125 ?
3
Shock
15000m/ s2,0.5ms
4
Vibration
10~2000Hz, 294m/s2
JGX-5125 Hermetical AC & DC Solid State Relay series
Main Technical Datatop ↑
JGX-5125 Hermetical AC & DC Solid State Relay series

Part

No.

In-put Voltage

(VDC)

In-put Current

(mA)

Reverse Voltage

(VDC)

Turn-off Voltage

(VDC)

Turn-on Voltage

(VDC)

005-50-

3~7

=15

7

=1

=4

010-50-

10~32

=20

32

=2.5

=10

JGX-5125 Hermetical AC & DC Solid State Relay series