Keywords:  *
SLC-RELAY
Microelectromagnetic Relay with Contact Resistance <=100mohm
Product solid picturetop ↑
SLC-RELAY
SLC-RELAY Relays Product solid picture
SLC-RELAY
Brief introductiontop ↑
SLC-RELAY
·Up to 30A switching in SPST and 20A switching in SPDT arrangements.
·Available as an open-frame relay, with a snap-on dust cover or with an immersion cleanable, plastic sealed case.
·Meets UL508 spacing requirements.
SLC-RELAY
specificationtop ↑
SLC-RELAY
Contact form
1a, 1b, 1c
Rated load
20A-240VAC/28VDC,30A-240VAC/28VDC
Contact resistance
<=100m (ohm)
Electrical life
100,000
Mechanical life
10,000,000
Coil rated voltage
5-24VDC
Coil power
0.93W
Coil pick-up voltage
<=75%
Coil drop-out voltage
>=10%
Ambient temperature
-25 degrees Celsius to +70 degrees Celsius
Coil and contacts
2000VAC/min
Contact and contacts
1500VAC/min
Insulation resistance
>=100M (ohm)
Mounting form
PCB
Weight (g)
34
Outline dimensions (mm)
32.1 x26.9 x 28.0
SLC-RELAY
Product Informationtop ↑
SLC-RELAY

SLC
XX VDC
S
L
C
Model of relay
Nominal coil voltage
Structure
Coil sensitivity
Contact form
SLC
05,06,09,12,18,24VDC
S:Sealed type
L:0.93W
A:1 form A
B:1 form B
F:Flux free type
D:Special
C:1 form C

SLC-RELAY
Outline Mounting Dimensionstop ↑
SLC-RELAY

DIMENSION(unit:mm)
DRILLING(unit:mm)
WIRING DIAGRAM
SLC-RELAY Relays Outline Mounting Dimensions

SLC-RELAY
Applicationstop ↑
SLC-RELAY
·Used for power switching, Electrical Heater, ventilator, Air conditioning,
·Refrigerating, Automobile and House-hold Appliance.

 

SLC-RELAY
Performancetop ↑
SLC-RELAY

Type
Item
SLC
Contact Resistance
100m?Max.
Operation Time
15msec Max.
Release Time
10msec Max.
Dielectric Strength
Between coil & contact Between contacts
2000VAC 1500VAC
Insulation Resistance
100 M?Min. (500VDC)
Max. ON/OFF Switching Mechanically
Electrically
300 operation/min
30 operation/min
Operating Ambient Temperature
-25°to +70°C (operating)
Operating Humidity
45 to 80% RH
Coil Temperature Rise
60 deg. Max.
Vibration
Endurance
Error Operation
10 to 55HZ Double Amplitude 1.5mm
10 to 55HZ Double Amplitude 1.5mm
Shock
Endurance
Error Operation
1000 m/sec (abt. 100g’s)
100 m/sec (abt. 10g’s)
Life Expectancy
Mechanically
Electrically
107
105
Weight
abt. 34grs.
UL File No.
E179944

SLC-RELAY
Ratingtop ↑
SLC-RELAY
20A/28VDC 240VAC
30A/28VDC 240VAC
CCEE
FILE NUMBER:CH0056447-2001
30A/250VDC
UL/CUL
FILE NUMBER:E179944
NO:20A/240VAC 28VDC NC:10A/240VAC 28VDC
TUV
FILE NUMBER:R9933789
NO:30A/240VAC 28VDC NC:20A/240VAC 28VDC
SLC-RELAY
Coil Data Charttop ↑
SLC-RELAY
COIL DATA CHART(AT20?)
Coil Sensitivity
Coil Voltage Code
Nominal Voltage
(VDC)
Nominal Current
(mA)
Coil Resistance
(O) ±10%
Power Consumption
(W)
Pull-In Voltage
(VDC)
Drop-Out Voltage
(VDC)
Max-Allowable Voltage
(VDC)
SLC
05
5
185
27
Abt.0.93
75%Max.
10% Max.
130%
06
6
150
40
09
9
93
97
12
12
77
155
24
24
36
660
SLC-RELAY
Contact Ratingtop ↑
SLC-RELAY
Type
Item
SLC
FORM A
FORM B
FORM C
N/O
N/C
Resistive Load (cosF=1General Motor)
30A 240VAC
30A 28VDC
240VAC
2HP
120VAC
1HP
15A 240VAC
10A 28VDC
240VAC
0.5 HP
120VAC
0.25HP
20A 240VAC
20A 28VDC
240VAC
2HP
120VAC
1HP
10A 240VAC
10A 28VDC
240VAC
0.5HP
120VAC
0.25HP
Ballast
10A 277VAC
3A 277VAC
10A 277VAC
3A 277VAC
LRA/FLA
240VAC
80/30
24 VAC 30/10
240VAC
50/20
240VAC 20/7
SLC-RELAY
Reference Datatop ↑
SLC-RELAY

SLC-RELAY Relays Reference Data
SLC-RELAY Relays Reference Data

SLC-RELAY