Keywords:  *
CHZ-1 Direct Current Contactor seriesTotal > RELAYS > Special Relay > CHZ-1 Direct Current Contactor series
CHZ-1 Direct Current Contactor series
CHZ-1 Direct Current Contactor using in the hard environmental condition
Brief introductiontop ↑
CHZ-1 Direct Current Contactor series
CHZ-1 Direct Current Contactor using in the hard environmental condition
CHZ-1 Direct Current Contactor series
specificationtop ↑
CHZ-1 Direct Current Contactor series
Coil power (W)
=5.6(stable)
Load Range of Contact Resistance
1 ~100A
1~32Vd.c.
Contact Resistance (mO)
Initial Value
=150
After Life Testing
=200
Insulation
Resistance
(MO)
Normal
=100
Maximum Switching Power
3200W
High Level Life
=10
Contact Load and Life
100A,32 Vd.c., 10,000 operations
Dielectric Strength
Vr.m.s.
(50Hz)
Normal Pressure
500
Low Pressure
300
Weight(g)
=250
CHZ-1 Direct Current Contactor series
how to ordertop ↑
CHZ-1 Direct Current Contactor series
CHZ-1   /  RJ3.610.001 
(1)          (2)    
(1) Model No.
(2) Specification NO.
CHZ-1 Direct Current Contactor series
Environmental Conditiontop ↑
CHZ-1 Direct Current Contactor series
Ambient Temperature Range (?)
-50~50?
Relative Humidity
98%(at 25?)
Vibration Resistance
Double swing1.6mm,50Hz
Acceleration(m/s2)
78
CHZ-1 Direct Current Contactor series
Main Technical Datatop ↑
CHZ-1 Direct Current Contactor series
No.
Rating Working Voltage
25?
Temperature range
 
Coil Resistance(O)±8%
Working Voltage(Max)
Release Voltage
Working Voltage(Max)
Release Voltage
 
Startup
Holding
 
RJ3.610.001
27
4
135
13.5
1.5~9.0
21.6
1.1~13.5
RJ3.610.003
48
12
512
28.8
2.9~16.0
38.4
1.9~24.0
RJ3.610.005
60
20
680
36.0
3.6~20.0
48.0
2.4~30.0
RJ3.610.007
110
65
2165
66.0
6.6~36.0
88.0
4.4~55.0
RJ3.610.009
24
3
108
14.4
1.4~8.0
19.2
1.0~12.0
CHZ-1 Direct Current Contactor series