1. Rated voltage (see table 1) table 1 Atmospheric pressure (P a) | Rated voltage (V) | AC Frequency (Hz) | 101326(760 mmH g) | 500 | 400 | 2266(17 mmH g) | 250 | 400 | 1000(7.5mmH g) | 200 | 400 |
Note : Connector Y56E (XKE) -1103 at atmospheric pressure for a 101326 P (760 mmHg), its rated working voltage of 115V. 2. Contact dual contact resistance (see table 2)
table 2 Contact dual diameter (mm) | f1.0 | f1.5 | f2.0 | f3.0 | Contact resistance (mO) | =5 | =2.5 | =1.5 | =0.75 |
Note : Seal Connector contact resistance of less than table provides three times the value. 3. Insulation resistance (see table 3) table 3 Environment | Insulation resistance | Normalcy | 3000MO | Moisture state (40 ° C, relative humidity of 95 ~ 98%) | 100 MO | High temperature(160?) | 500 MO |
4. Contact dual rated current (see table 4) table 4 Contact dual diameter(mm) | Actual ohmic contacts even | Current ratings (A) | f1.0 | 1~15 | 5 | 16~29 | 4.5 | 30~40 | 4 | 41~61 | 3.5 | f1.5 | 1~10 | 10 | 11~16 | 9 | 17~20 | 8 | f2.0 | 1~5 | 20 | 6~10 | 18 | f3.0 | 1~2 | 40 | 3~4 | 36 | 5~8 | 32 |
5. Dielectric strength (see Table 5) Table 5 Environment | Test voltage (V) (50 Hz RMS) | Duration (min) | Normalcy | 1500 | 1 | Moisture state (40 ° C, relative humidity of 95 ~ 98%) | 1125 | Low temperature and low pressure State | -60? 2266P a(17 mmH g) | 375 | -60? 1000P a(7.5 mmH g) | 250 |
Note : Y56E (XKE) -1103 Connector in the normal state test voltage of 1000V;
In humid conditions test voltage of 500V; The low temperature and low pressure (-60 ° C, 2266P a) state test voltage of 175V. 6. Shell contact resistance Connector shell combine all of the total contact resistance less than 0.05 ohm 7. Contact dual Single separation force (see Table 6) Table 6
Contact dual diameter(mm) | Even a single exposure Pullout (N) | f1.0 | 1.0~3.0 | f1.5 | 1.5~4.0 | f2.0 | 2.5~5.0 | f3.0 | 3.9~6.9 |
8. Mechanical life connecting separation 500 Classification and specifications
Serial | Characteristics said | markings | Remarks | 1 | Plug Block, said the main code | Y56E(XKE) | | 2 | Socket and panels with diameter (type) | 11?14?18?24?27?30?36 | | 3 | Install disk shape | Side | No markings | | Disk | Y | | 4 | Contact dual type | Pin | CRIMPING | F | | Welded | J | For sealed socket | Jack | CRIMPING | R | | 5 | Even the total number of contacts | Figures indicated | | 6 | Plug socket types | Socket | Non-sealed | Z | | Sealed | M | | Plug | No markings | | 7 | The tail structure | Shielding | P | | Straight down the line | Q | | | | Bend-pressure line | S | | Guarding Pipe Line | W | | No rear annex | No markings | | 8 | The shell variable bit keys | Normal bond | No markings | | First-change keys | 1 | | second key change | 2 | | third key change | 3 | | fourth change keys | 4 | | 9 | Socket installation code form | Before installing sockets | No markings | | After installing sockets | H | | 10 | Modification code | | A?B?C… | Under the modified code Chinese pinyin alphabetical order (O.I not use) | | | | | | | | |
Insulation installed with a hole-randed(from the surface to see inserted a needle board insulation installed holes) Table 7 Bond-angle | ?1 | ?2 | ?3 | ?4 | 1100 | Remaining | 1100 | Remaining | 1100 | Remaining | 1100 | Remaining | Normal bond | 1050 | 1400 | 2150 | 2650 | First-change keys | 1020 | 1320 | 2480 | 3200 | Second key change | 800 | 1180 | 2300 | 3120 | Third key change | 350 | 1400 | 2350 | 2050 | 2750 | Fourth change keys | 1100 | 640 | 1550 | 2340 | 2700 | 3040 | | | | | | | | | |
|