Contact form
6Z(mechanical contact)
time lapse range
0.1 ~ 500
Contact loading
Resistive: 1A , 28Vd.c.
time lapse precision
±5%(atT≤0.5s ) ±2%(atT>0.5s)
Contact Resistance (Ω)
Before test
≤ 0.1
time lapse style
1,3,4,5
After life
≤ 0.15
Working voltage
24~ 32Vd.c.
Insulation
resistance(MΩ)
normal temperature
normal humidity
≥ 500
High temperature
high humidity
≥ 10
Dielectric strengthVr.m.s.(50Hz)
Normal
500
Life
10,000 Operations
or 50h
(on first coming basis)
Low low pressure
200
Weight(g)
≤ 35
JSB-243M / 2 I – 50 - 60
(1) (2) (3) (4) (5)
(1)model
(2)mounting code
(3)environment grade
(4)T1 time lapse standard
(5)T2 time lapse standard
item
Environmental grade
I
Ambient Temperature Range (℃)
-40~85
relative humidity
95%(at 40℃)
low pressure (kPa)
0.27
vibration resistance
frequency coverage (Hz)
10 ~ 2000
acceleration (m/s2)
300
Shock Resistance
750
Impulse length (ms)
6