Keywords:  *
JSB-55MP Hermetical Mixed Time-lapse Relay series
JSB-55MP Hermetical Mixed Time-lapse Relay using in the hard environmental condition
JSB-55MP Hermetical Mixed Time-lapse Relay series JSB-55MP Hermetical Mixed Time-lapse Relay series
Brief introductionJSB-55MP Hermetical Mixed Time-lapse Relay series JSB-55MP Hermetical Mixed Time-lapse Relay seriestop ↑
JSB-55MP Hermetical Mixed Time-lapse Relay series JSB-55MP Hermetical Mixed Time-lapse Relay series
JSB-55MP Hermetical Mixed Time-lapse Relay using in the hard environmental condition
JSB-55MP Hermetical Mixed Time-lapse Relay series JSB-55MP Hermetical Mixed Time-lapse Relay series
specificationJSB-55MP Hermetical Mixed Time-lapse Relay series JSB-55MP Hermetical Mixed Time-lapse Relay seriestop ↑
JSB-55MP Hermetical Mixed Time-lapse Relay series JSB-55MP Hermetical Mixed Time-lapse Relay series
Working Voltage
27±10﹪
Load Range of Contact Resistance
0.1~5A
1~30Vd.c.
5~115Va.c.
Input Electric Current(mA)
≤50
Timing Exactly Degree
≤±5﹪
Contact Resistance (mΩ)
Initial Value
≤50
Maximum Switching Power
140W,230VA
After Life Testing
≤200
Contact Load and Life
5A,28 Vd.c.,
 20,000 operations
2A,115Va.c.,
 20,000 operations
Insulation
Resistance
(MΩ)
Normal
≥1000
High Level Life
≥100
Dielectric Strength
Vr.m.s.
(50Hz)
Normal Pressure
500
Weight(g)
≤13
Low Pressure
300
Sealing Property
leak rate≤ 0. 1 Pa.cm3/s
Can supply≤ 0.001 Pa.cm3/s
JSB-55MP Hermetical Mixed Time-lapse Relay series JSB-55MP Hermetical Mixed Time-lapse Relay series
how to orderJSB-55MP Hermetical Mixed Time-lapse Relay series JSB-55MP Hermetical Mixed Time-lapse Relay seriestop ↑
JSB-55MP Hermetical Mixed Time-lapse Relay series JSB-55MP Hermetical Mixed Time-lapse Relay series

JSB-55MP  /  2s    -  2    1        H  

(1)       (2)      (3)   (4)   (5)   (6)    

(1) Model NO.

(2) Time-lapse Time

(3) Install type No

(4)Outlet Terminal Type No.

(5)Environment Grade No.

(6)Temperature Grade No.

JSB-55MP Hermetical Mixed Time-lapse Relay series JSB-55MP Hermetical Mixed Time-lapse Relay series
Environmental ConditionJSB-55MP Hermetical Mixed Time-lapse Relay series JSB-55MP Hermetical Mixed Time-lapse Relay seriestop ↑
JSB-55MP Hermetical Mixed Time-lapse Relay series JSB-55MP Hermetical Mixed Time-lapse Relay series
Environment Grade
Ambient Temperature Range (℃)
L grade:-55~85℃; H grade: -55~125℃
Relative Humidity
98%(at 40℃)
Low Pressure (kPa)
1
Vibration Resistance
98m/s2 ,10~500 Hz
147m/s2 ,10~2000 Hz
196m/s2 ,10~2000 Hz
Shock Resistance(m/s2)
245
490
735
Acceleration(m/s2)
245
490
490
JSB-55MP Hermetical Mixed Time-lapse Relay series JSB-55MP Hermetical Mixed Time-lapse Relay series