Keywords:  *
GK-3 Separate control over loading switchTotal > RELAYS > Special Relay > GK-3 Separate control over loading switch
GK-3 Separate control over loading switch
The product is acceleration-sensitive device with function of interlock protect .
brief introductionGK-3 Separate control over loading switch GK-3 Separate control over loading switchtop ↑
GK-3 Separate control over loading switch GK-3 Separate control over loading switch
The product is acceleration-sensitive device with function of interlock protect before using and provides big and small over loading accelerations with the two corresponding contacts switch states. They are suitable for controlling flight for aerocraft and the relays needing double acceleration control.
GK-3 Separate control over loading switch Relays brief introduction
GK-3 Separate control over loading switch GK-3 Separate control over loading switch
specificationGK-3 Separate control over loading switch GK-3 Separate control over loading switchtop ↑
GK-3 Separate control over loading switch GK-3 Separate control over loading switch
Specification
Contact arrangement
2Z
Acceleration Specification
The acceleration up to 45~65m/s2, the contacts switch(normal open turn on)
 The acceleration low to 0~7m/s2 the contacts switch(normal close turn on)
unlock Voltage Rating
20~27 Vd.c.
Contact Resistance(O)
Before life
=0.05
Contact rating
resistive:1A,27Vd.c.
After life
=0.10
Insulation Resistance
(MO)
Under normal condition
=500
Under high temperature and high humidity
=5
Dielectric Strength
Vr.m.s.(50Hz)
Under normal condition
300
Durability
500 times
Under low atmospheric pressure
150
weight(g)
=175
Function Specification
Acceleration Setting Value:24~26g
?If you need relays with the other acceleration value, connect us?
GK-3 Separate control over loading switch GK-3 Separate control over loading switch
how to orderGK-3 Separate control over loading switch GK-3 Separate control over loading switchtop ↑
GK-3 Separate control over loading switch GK-3 Separate control over loading switch
How To Order
GK-3 Separate control over loading switch Relays how to order
????????= upper limit value of Operating acceleration
????????=lower limit value of Operating acceleration
????=product type
Enterprise standard code:Q/LJ.J(02)32
GK-3 Separate control over loading switch GK-3 Separate control over loading switch
Environmental ConditionGK-3 Separate control over loading switch GK-3 Separate control over loading switchtop ↑
GK-3 Separate control over loading switch GK-3 Separate control over loading switch
Environmental Condition
No.
Item
Data
1
Ambient Temperature Range(?)
-55~+85
2
Relative Humidity
Up to 95% at +40?
3
Low atmospheric pressure(kPa)
0.3
4
Vibration
Frequency range(Hz)
10~2000
Acceleration(m/s2)
150
5
Shock
Acceleration(m/s2)
500
Pulse duration(ms)
11
GK-3 Separate control over loading switch GK-3 Separate control over loading switch
Outline Mounting Dimensions and Bottom View CircuitGK-3 Separate control over loading switch GK-3 Separate control over loading switchtop ↑
GK-3 Separate control over loading switch GK-3 Separate control over loading switch
Outline Mounting Dimensions and Bottom View Circuit
GK-3 Separate control over loading switch Relays Outline Mounting Dimensions and Bottom View Circuit
?????= Bottom View Circuit  ?????=Terminal type
GK-3 Separate control over loading switch GK-3 Separate control over loading switch
Load CharacteristicsGK-3 Separate control over loading switch GK-3 Separate control over loading switchtop ↑
GK-3 Separate control over loading switch GK-3 Separate control over loading switch
Load Characteristics
GK-3 Separate control over loading switch Relays Load Characteristics
GK-3 Separate control over loading switch GK-3 Separate control over loading switch