Keywords:  *
SRC-RELAY
Microelectromagnetic Relay with Services Guaranteed
Product solid pictureSRC-RELAY SRC-RELAYtop ↑
SRC-RELAY SRC-RELAY
SRC-RELAY Relays Product solid picture
SRC-RELAY SRC-RELAY
Brief introductionSRC-RELAY SRC-RELAYtop ↑
SRC-RELAY SRC-RELAY
·2 Form C(DPDT) bifurcated-cross-bar contacts.
·Gold Clad silver contact.
·Dip-2C type matching 16 pin IC socket.
·Sealed type available.
·UL recognized.
·High sensitivity.
·Coil Power Consumption:0.20~0.50W
SRC-RELAY SRC-RELAY
specificationSRC-RELAY SRC-RELAYtop ↑
SRC-RELAY SRC-RELAY
Contact form
2c
Rated load
1A-250VAC/30VDC ,2A-125VAC/30VDC
Contact resistance
<=50m (ohm)
Electrical life
100,000
Mechanical life
10,000,000
Coil rated voltage
3-24VDC
Coil power
0.20W, 0.36W ,0.45W
Coil pick-up voltage
<=75%
Coil drop-out voltage
>=10%
Ambient temperature
-25 degrees Celsius to +55 degrees Celsius
Coil and contacts
500VAC/min
Contact and contacts
500VAC/min
Insulation resistance
>=100M (ohm)
Mounting form
PCB
Weight (g)
6
Outline dimensions (mm)
20.2 x 10.0 x 12.5
SRC-RELAY SRC-RELAY
Product InformationSRC-RELAY SRC-RELAYtop ↑
SRC-RELAY SRC-RELAY
SRC
XX VDC
S
C
Model of relay
Nominal coil voltage
Structure
Contact form
SRC
03,05,06,09,12,24,48VDC
S:Sealed type
H:0.20W
F:Flux free type
L:0.36W
D:0.45W
SRC-RELAY SRC-RELAY
Outline Mounting DimensionsSRC-RELAY SRC-RELAYtop ↑
SRC-RELAY SRC-RELAY
DIMENSION(unit:mm)
DRILLING(unit:mm)
WIRING DIAGRAM
SRC-RELAY Relays Outline Mounting Dimensions
SRC-RELAY SRC-RELAY
ApplicationsSRC-RELAY SRC-RELAYtop ↑
SRC-RELAY SRC-RELAY
·Telecommunication equipment,domestic appliances,office machines,audio equipment, etc.

 

SRC-RELAY SRC-RELAY
PerformanceSRC-RELAY SRC-RELAYtop ↑
SRC-RELAY SRC-RELAY
Type
Item
SRC
Contact Resistance
100m?Max.
Operation Time
8msec Max.
Release Time
5msec Max.
Dielectric Strength Between coil & contact Between contacts
500VAC 50/60Hz (1 minute) 500VAC 50/60Hz (1 minute)
Insulation Resistance
1000 M?Min. (500VDC)
Max. ON/OFF Switching Mechanically Electrically
300 operation/min 30 operation/min
Operating Ambient Temperature
-25°C to +55°C
Operating Humidity
45 to 85% RH
Vibration Endurance Error Operation
10 to 55Hz Double Amplitude 1.5mm
10 to 55Hz Double Amplitude 1.5mm
Shock Endurance Error Operation
100G Min. 10G Min.
Life Expectancy Mechanically Electrically
107 ops. Min. (no load) 105 ops. Min.
Weight
abt. 6grs.
SRC-RELAY SRC-RELAY
RatingSRC-RELAY SRC-RELAYtop ↑
SRC-RELAY SRC-RELAY

UL/CUL
FILE NUMBER:E167996
1A/120VAC 30VDC
1A/120VAC 30VDC

SRC-RELAY SRC-RELAY
Coil Data ChartSRC-RELAY SRC-RELAYtop ↑
SRC-RELAY SRC-RELAY

Coil Sensitivity
Coil Voltage Code
Nominal Voltage (VDC)
Nominal Current (mA)
Coil Resistance (O) ±10%
Power Consumption (W)
Pull-In Voltage (VDC)
Drop-Out Voltage (VDC)
Max-Allowable Voltage
(VDC)
SRC-L
03
3
120
25
Abt.0.36W
75%Max.
5%Min.
150%
05
5
71.4
70
06
6
60
100
09
9
40.9
220
12
12
30
400
24
24
15
1600
SRC-H
03
3
66.7
45
Abt.0.2W
75%Max.
5%Min.
150%
05
5
40
125
06
6
33.3
180
09
9
22.2
405
12
12
16.7
720
24
24
8.3
2880
SRC-D
48
48
8.3
5760
Abt.0.4W

SRC-RELAY SRC-RELAY
Contact RatingSRC-RELAY SRC-RELAYtop ↑
SRC-RELAY SRC-RELAY

Type
Item
SRC
Contact Capacity Resistive Load (cosF=1)
1A 120VAC / 1A 30VDC
Inductive Load (cosF=0.4 L/R=7msec.)
0.5A 120VAC/ 0.5A 30VDC
Rated Carrying Current
1A
Max. Allowable Voltage
120VAC, 28VDC
Max. Allowable Current
1A
Referenced Min. Applicable Load
100mVDC 0.1mA
Contact Material
AgCdO+ Au Clad

SRC-RELAY SRC-RELAY
Reference DataSRC-RELAY SRC-RELAYtop ↑
SRC-RELAY SRC-RELAY

SRC-RELAY Relays Reference Data
SRC-RELAY Relays Reference Data
SRC-RELAY Relays Reference Data

SRC-RELAY SRC-RELAY