SRB-RELAY |
Microelectromagnetic Relay with PCB Mounting Form
|
|
|
Brief introductionSRB-RELAY SRB-RELAY | top ↑ |
SRB-RELAY SRB-RELAY· Switching capacity available by 3A in spite of small size design for highdensity P.C. board mounting technique. · Selection of plastic material for high temperature and better chemical solution performance. · Sealed types available. · Simple relay magnetic circuit to meet low cost of mass production. | SRB-RELAY SRB-RELAY |
specificationSRB-RELAY SRB-RELAY | top ↑ |
SRB-RELAY SRB-RELAYContact form | 1a, 1b, 1c | Rated load | 3A-125VAC/28VDC,1A 240VAC/28VDC | Contact resistance | <=50m (ohm) | Electrical life | 100,000 | Mechanical life | 10,000,000 | Coil rated voltage | 3-48VDC | Coil power | 0.36W, 0.45W | Coil pick-up voltage | <=75% | Coil drop-out voltage | >=10% | Ambient temperature | -25 degrees Celsius to +70 degrees Celsius | Coil and contacts | 750VAC/min | Contact and contacts | 750VAC/min | Insulation resistance | >=100M (ohm) | Mounting form | PCB | Weight (g) | 10 | Outline dimensions (mm) | 19.0 x 15.5 x 15.0 | SRB-RELAY SRB-RELAY |
Product InformationSRB-RELAY SRB-RELAY | top ↑ |
SRB-RELAY SRB-RELAYSRB | XX VDC | C | L | C | Model of relay | Nominal coil voltage | Contact form | Coil sensitivity | Contact form | SRB | 03,05,06,09,12,24VDC | S:Sealed type | L: 0.36W | A:1 form A | B:1 form B | F:Flux free type | D:0.45W | C:1 form C |
SRB-RELAY SRB-RELAY |
ApplicationsSRB-RELAY SRB-RELAY | top ↑ |
SRB-RELAY SRB-RELAY· Domestic appliance, office machine, audio, equipment, automobile, etc. |
SRB-RELAY SRB-RELAY |
PerformanceSRB-RELAY SRB-RELAY | top ↑ |
SRB-RELAY SRB-RELAYType Item | SLC | Contact Resistance | 100m?Max. | Operation Time | 10msec Max. | Release Time | 5msec Max. | Dielectric Strength Between coil & contact Between contacts | 1000VAC 50/60HZ (1 minute) 500VAC 50/60 HZ (1 minute) | Surge Resistiveness | 3000V (between coil & contact 1×40 usec) | Insulation Resistance | 100 M?Min. (500VDC) | Max. ON/OFF Switching Mechanically Electrically | 300 operation/min 30 operation/min | Operating Ambient Temperature | -30? to +80? (No water condensation and no water drop) | Operating Humidity | 45 to 85% RH | Vibration Endurance Error Operation | 10 to 55Hz Double Amplitude 1.5mm 10 to 55Hz Double Amplitude 1.5mm | Shock Endurance Error Operation | 100G Min. 10G Min. | Life Expectancy Mechanically Electrically | 1×108operations. Min. (no load) 1×104 operations. Min (at rated coil voltage). | Weight | Abt. 10grs. | SRB-RELAY SRB-RELAY |
RatingSRB-RELAY SRB-RELAY | top ↑ |
SRB-RELAY SRB-RELAY1A/240VAC 28VDC | 3A/125VAC 28VDC | SRB-RELAY SRB-RELAY |
Coil Data ChartSRB-RELAY SRB-RELAY | top ↑ |
SRB-RELAY SRB-RELAYCoil Sensitivity | Coil Voltage Code | Nominal Voltage (VDC) | Nominal Current (mA) | Coil Resistance O(±10%) | Power Consumption (W) | Pick-In voltage (VDC) | Drop-out voltage (VDC) | Max-Allowable Voltage (VDC) | SRB (High Sensitivity) | 03 | 03 | 120 | 25 | Abt.0.36W | 75%Max. | 5% Min. | 120% | 05 | 05 | 71.4 | 70 | 06 | 06 | | 100 | 09 | 09 | 40 | 225 | 12 | 12 | 30 | 400 | 24 | 24 | 15 | 1600 | 48 | 48 | 7.5 | 6400 | Standard Sensitivity | 03 | 03 | 150 | 20 | Abt.0.45W | 75% Max. | 5% Min. | 110% | 05 | 05 | 89.3 | 55 | 06 | 06 | 75 | 80 | 09 | 09 | 50 | 180 | 12 | 12 | 37.5 | 320 | | 24 | 18.7 | 1280 |
SRB-RELAY SRB-RELAY |
Contact RatingSRB-RELAY SRB-RELAY | top ↑ |
SRB-RELAY SRB-RELAYType Item | SRB | Contact Capacity Resistive Load (cosF=1) | 1A 240VAC 28VDC 3A/125VAC 28VDC | Rated Carrying Current | 1A | Max. Allowable Voltage | 250VAC/110VDC | Max. Allowable Current | 3A | Max. Allowable Power Force | 360VAC/70W | Contact Material | Ag Alloy | SRB-RELAY SRB-RELAY |
|