Keywords:  *
SLF-RELAY
Microelectromagnetic Relay with Contact Form 1A
Product solid pictureSLF-RELAY SLF-RELAYtop ↑
SLF-RELAY SLF-RELAY
SLF-RELAY Relays Product solid picture
SLF-RELAY SLF-RELAY
Brief introductionSLF-RELAY SLF-RELAYtop ↑
SLF-RELAY SLF-RELAY
·1 Form A (SPST-NO) Contact.
·Heavy duty switching current up to 30A.
·High inrush current 65A.
·High surge voltage 10,000V.
·Small package - Meet high density mounting requirement.
·Meet with associated requirement for UL508 industrial control equipment.
·With 4,000VAC standing.
SLF-RELAY SLF-RELAY
specificationSLF-RELAY SLF-RELAYtop ↑
SLF-RELAY SLF-RELAY
Contact form
1a
Rated load
30A-250VAC/28VDC
Contact resistance
<=100m (ohm)
Electrical life
100,000
Mechanical life
10,000,000
Coil rated voltage
3-24VDC
Coil power
1.2W
Coil pick-up voltage
<=75%
Coil drop-out voltage
>=10%
Ambient temperature
-40 degrees Celsius to +70 degrees Celsius
Coil and contacts
4000VAC/min
Contact and contacts
1200VAC/min
Insulation resistance
>=100M (ohm)
Mounting form
FASTEN
Weight (g)
55
Outline dimensions (mm)
35.2x 32.2 x 24.2
SLF-RELAY SLF-RELAY
Product InformationSLF-RELAY SLF-RELAYtop ↑
SLF-RELAY SLF-RELAY

SLF
XX VDC
S
L
C
Model of relay
Nominal coil voltage
Structure
Coil sensitivity
Contact form
SLF
05,06,09,12,18,24VDC
S:Sealed type
L: 1.2W
A:1 form A
F:Flux free type
D:Special

 

SLF-RELAY SLF-RELAY
Outline Mounting DimensionsSLF-RELAY SLF-RELAYtop ↑
SLF-RELAY SLF-RELAY

DIMENSION(unit:mm)
DRILLING(unit:mm)
WIRING DIAGRAM
SLF-RELAY Relays Outline Mounting Dimensions

SLF-RELAY SLF-RELAY
ApplicationsSLF-RELAY SLF-RELAYtop ↑
SLF-RELAY SLF-RELAY
·Used on air conditioner, electrical heater Remote-controlled TV, automatic control and household electric device.
SLF-RELAY SLF-RELAY
PerformanceSLF-RELAY SLF-RELAYtop ↑
SLF-RELAY SLF-RELAY
Type
Item
SLF
Contact Resistance
50m?Max. (at 1A 6VDC)
Operation Time
20msec Max.
Release Time
5msec Max.
Dielectric Strength Between coil & contact Between contacts
4000VAC 50/60Hz (1 minute)
1200VAC 50/60Hz (1 minute)
Surge Resistiveness
1000V (at 1.2×50msec standard surge wave)
Insulation Resistance
100 M?Min. (500VDC)
Max. ON/OFF Switching Mechanically
Electrically
300 operation/min
30 operation/min
Operating Ambient Temperature
-40°C to +70°C
(No water drop condensation)
Operating Humidity
45 to 85% RH
Coil Temperature Rise
35 deg. Max. (at rated coil voltage)
Vibration
Endurance
Error Operation
10 to 55HZ Double Amplitude 1.5mm
10 to 55HZ Double Amplitude 1.5mm
Shock
Endurance
Error Operation
200m/s2 (11 ±1msec)
1000m/s2 (6 ±1msec)
Life Expectancy
Mechanically
Electrically
5 ×106 ops. Min. (no load)
1 ×105 ops. Min. (at resistive load)
Weight
abt. 55grs.
SLF-RELAY SLF-RELAY
RatingSLF-RELAY SLF-RELAYtop ↑
SLF-RELAY SLF-RELAY
30A/250VAC 28VDC

 

SLF-RELAY SLF-RELAY
Coil Data ChartSLF-RELAY SLF-RELAYtop ↑
SLF-RELAY SLF-RELAY

Coil Sensitivity
Coil Voltage Code
Nominal
Voltage
(VDC)
Nominal
Current
(mA)
Coil Resistance
O(±10%)
Power Consumption
(W)
Pick-In voltage
(VDC)
Drop-out voltage
(VDC)
Max-Allowable Voltage
(VDC)
SLF
05
05
239
38
Abt.1.2W
75% Max.
10% Min.
110% Max
06
06
200
55
09
09
134.3
125
12
12
100
222
18
18
66.7
500
24
24
50
890

 

SLF-RELAY SLF-RELAY
Contact RatingSLF-RELAY SLF-RELAYtop ↑
SLF-RELAY SLF-RELAY

Type Item
SLF
Contact Capacity Resistive Load
30A 125VAC
Motor Load
2HP 250VAC
Rated Carrying Current
30A
Max. Allowable Voltage
250VAC, 30VDC
Max. Allowable Current
30A
Max. Allowable Power Force
7500VA
Referenced Min. Applicable Load
5VDC, 100mA
Contact Material
AgCdO

SLF-RELAY SLF-RELAY
Reference DataSLF-RELAY SLF-RELAYtop ↑
SLF-RELAY SLF-RELAY

SLF-RELAY Relays Reference Data

SLF-RELAY SLF-RELAY