SRI-RELAY |
Microelectromagnetic Relay with Weigh of 12g
|
|
|
Brief introductionSRI-RELAY SRI-RELAY | top ↑ |
SRI-RELAY SRI-RELAY·SRI series relay covers switching capacity from dry circuit by 10A to comply with user’s wide selection. ·2.54mm terminal pitch employment equal to I.C. terminal pitch. ·Employment of suitable plastic materials to be applied to high temperature and various chemical solutions. ·Complete protective construction from dust and soldering flux. If required.Plastic epoxy resin sealed type is available for washing procedure | SRI-RELAY SRI-RELAY |
specificationSRI-RELAY SRI-RELAY | top ↑ |
SRI-RELAY SRI-RELAYContact form | 1a, 1b, 1c | Rated load | 10A-125VAC, 10A-28VDC | Contact resistance | <=100m (ohm) | Electrical life | 100,000 | Mechanical life | 10,000,000 | Coil rated voltage | 3-48VDC | Coil power | 0.36W, 0.45W | Coil pick-up voltage | <=75% | Coil drop-out voltage | >=10% | Ambient temperature | -25 degrees Celsius to +70 degrees Celsius | Coil and contacts | 2000VAC/min | Contact and contacts | 1000VAC/min | Insulation resistance | >=100M (ohm) | Mounting form | PCB | Weight (g) | 12 | Outline dimensions (mm) | 22.3 x 17.3 x 15.0 | SRI-RELAY SRI-RELAY |
Product InformationSRI-RELAY SRI-RELAY | top ↑ |
SRI-RELAY SRI-RELAYSRI | XX VDC | S | D | C | Model of relay | Nominal coil voltage | Structure | Coil sensitivity | Contact form | SRI | 03,05,06,09,12,18,24,48 VDC | S:Sealed type | D: 0.45W | A:1 form A | B:1 form B | F:Flux free type | C:1 form C | SRI-RELAY SRI-RELAY |
ApplicationsSRI-RELAY SRI-RELAY | top ↑ |
SRI-RELAY SRI-RELAY·Cooling Appliance, air conditioner, audio equipment, domestic appliance,car control unit, etc. | SRI-RELAY SRI-RELAY |
PerformanceSRI-RELAY SRI-RELAY | top ↑ |
SRI-RELAY SRI-RELAYType Item | SRI | Contact Resistance | 50m?Max. | Operation Time | 8msec Max. | Release Time | 4msec Max. | Dielectric Strength Between coil & contact Between contacts | 2000VAC 50/60HZ(1 minute) 1000VAC 50/60HZ(1 minute) | Surge Resistiveness | 3500V(between coil & contacts 1×40 usec.) | Insulation Resistance | 100 M? Min. (500VDC) | Max. ON/OFF Switching Mechanically Electrically | 300 operation/min 30 operation/min | Ambient Temperature | -25? to +70? | Operating Humidity | 45 to 85% RH | Coil Temperature Rise | 50 deg.Max. | Vibration Endurance Error Operation | 10 to 55Hz Double Amplitude 1.5mm 10 to 55Hz Double Amplitude 1.5mm | Shock Endurance Error Operation | 1000m/sec2 (abt.100G) 100m/sec2 (abt.10G) | Life Expectancy Mechanically Electrically | 107 Operations. Min. (no load) 105 Operations. Min. (at rated coil voltage) | Weight | Abt.10grs | SRI-RELAY SRI-RELAY |
RatingSRI-RELAY SRI-RELAY | top ↑ |
SRI-RELAY SRI-RELAY10A/125VAC 28VDC | 5A/240VAC 28VDC | SRI-RELAY SRI-RELAY |
Coil Data ChartSRI-RELAY SRI-RELAY | top ↑ |
SRI-RELAY SRI-RELAYCoil Sensitivity | Coil Voltage Code | Nominal Voltage (VDC) | Nominal Current (mA) | Coil Resistance O(±10%) | Power Consumption (W) | Pick-In voltage (VDC) | Drop-out voltage (VDC) | Max-Allowable Voltage (VDC) | Standard Sensitivity | 03 | 3 | 150 | 20 | Abt.0.45W | 75% Max. | 10% Min. | 130% | 05 | 5 | 89 | 56 | 06 | 6 | 75 | 80 | 09 | 9 | 50 | 180 | 12 | 12 | 37.5 | 320 | 18 | 18 | 25 | 720 | 24 | 24 | 18.8 | 1280 | 48 | 48 | 12.6 | 3800 | Abt.0.61W | SRI-RELAY SRI-RELAY |
Contact RatingSRI-RELAY SRI-RELAY | top ↑ |
SRI-RELAY SRI-RELAYType Item | SRI | Contact Capacity Resistive Load (cos?=1) | 10A 120VAC 10A 28VDC | Rated Carrying Current | 10A | Max. Allowable Voltage | 250VAC,110VDC | Max. Allowable Current | 10A | ReferencedMin.Applicab Load | 1200VA,280W | Referenced Min. Applicable Load | 5VDC,100mA | Contact Material | AgCdO | SRI-RELAY SRI-RELAY |
|