Connector
Relay
Switch
Keywords:
*
Home
Products & Solutions
Products Catalog
Connector
D-SUB (Rectangle) Connector
RF Coaxial Connector
Circular Connector
Brush Off Connector
DIN41612 Connector
MS series Connector
Other Connector
Relays
Electromagnetism Relay
Magnetism Keep Relay
Automobile power Relay
Temperature Relay
Time Relay
Miniature power Relay
RF Coaxial Ralasy
Communication Relay
Special Relay
High power and hermetical relays
Magnetism Keep and hermetical relay series
1JS11-1 Time-lapse and hermetical relay series
Other Relay
Switch
Button Switch series
Rotary Switch series
Toggle Switch series
Brush Switch series
Tact Switch series
other Switch series
Cross Product
LEMO Cross connector
ODU Cross connector
Amphenol Cross connector
Support
Support Center
Careers
Who We Are
Company Profile
Vision & Mission
News & Events
Contact Us
JQ-37F Contactor using in the hard environmental condition series
Total
>
RELAYS
>
Other Relay
>
JQ-37F Contactor using in the hard environmental condition series
JQ-37F Contactor using in the hard environmental condition series
JQ-37F Contactor using in the hard environmental condition
Brief introduction
li>
specification
li>
how to order
li>
Environmental Condition
li>
Main Technical Data
li>
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
Brief introduction
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
top ↑
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
JQ
-37F
Contactor using in the hard environmental condition
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
specification
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
top ↑
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
Coil power (W)
≤7
Load Range of Contact Resistance
5~150A,
5~380Va.c.
Contact Resistance (mΩ)
Initial Value
≤50
After Life Testing
≤150
Insulation
Resistance
(MΩ)
Normal
≥1000
Maximum Switching Power
57000VA
High Level Life
≥100
Contact Load and Life
150A,380Va.c.,50Hz,3Φ, 10,000 operations
Dielectric Strength
Vr.m.s.
(50Hz)
Normal Pressure
1800
Low Pressure
400
Weight(g)
≤1300
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
how to order
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
top ↑
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
JQ-37F
/
024
-
1
(1) (2) (3)
(1) Model No.
(2) Specification NO.
(3)Installation Type No.
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
Environmental Condition
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
top ↑
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
Ambient Temperature Range (℃)
-55~85℃
Relative Humidity
98%(at 40℃)
Low Pressure (kPa)
2.5
Vibration
98m/s
2
, 10-500Hz
Shock Resistance(m/s
2
)
196
Acceleration(m/s
2
)
245
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
Main Technical Data
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
top ↑
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
No.
Coil voltage
25℃
Temperature range
Rated
Max
Coil Resistance
(Ω)±10%
Working Voltage
(Max)
Sustaining Voltage
(Max)
Release Voltage
(Min)
Working Voltage
(Max)
Sustaining Voltage
(Max)
Release Voltage
(Min)
Holding
Startup
024
24
26.4
82.0
6.0
15.1
7.2
1.7
20.0
12.0
1.0
027
27
29.7
103.5
7.5
18.0
8.1
1.9
23.0
13.5
1.1
036
36
39.6
185.0
13.0
24.0
10.8
2.5
30.6
18.0
1.5
060
60
66.0
510.0
36.0
40.0
18.0
4.2
51.0
30.0
2.5
110
110
121.0
1725.0
125.0
73.3
33.0
7.7
93.5
55.0
4.6
220
220
242.0
6920.0
500.0
154.0
74.0
22.9
182.6
110.0
13.8
JQ-37F Contactor using in the hard environmental condition series JQ-37F Contactor using in the hard environmental condition series
Tel: 86-755-86099789 Fax: 86-755-86018655 Email:sales@anovay.com
Address: 6th Floor,Block 12,JiuXiangLin Industrial Zone Xili Town,Nanshan District,Shenzhen 518055 P. R. China