Electrical Specifications(Ta=25℃) | AC |
In-put data | In-put Voltage (VDC) | 3~32 |
90~280 |
In-put Current (mA) | 3~32 | 18 |
90~280 | 20 |
Turn-off Voltage (V) | 3~32 | 1 |
90~280 | 25 |
Reverse Voltage (VDC) | 3~32 | 32 |
Out-put data | Rated out-put Current (A) | 60(JGX-24FX) |
70(JGX-1595FA) |
90(JGX-1599F) |
Maximum Surge Current (10ms) | 600A(JGX-24FX) |
700A(JGX-1595FA) |
840A(JGX-1599F) |
Rated Out-put Voltage (VAC) | 220 |
380 |
Zero Cross Voltage (VAC) | ±10 |
Out-put Voltage-drop (VAC) | 2 | (JGX-24FX) |
(JGX-1675FA) |
(JGX-1685F) |
Out-put Current leakage (mA) | 10 |
Power Dissipation (W/A) | 2 | (JGX-24FX) |
(JGX-1595FA) |
(JGX-1599F) |
Instantaneous Voltage (Vp) | 600(220V) |
800(380V) |
Turn on Time (ms) | 10 |
Turn off Time (ms) | 10 |
Operate Frequency (Hz) | 47~400 |
Voltage Index Rise (V/us) | 200 |
Insulation Resistance(MΩ) | 1000 |
Environmental Specifications | Dielectric Withstanding Voltage (Vr.m.s.) | 2000 |
Operating Temperature Range (℃) | -30~80 |
Stock Temperature (℃) | -40~100 |
Weight (g) | 120 |