Keywords:  *
JSB-44MA Hybrid Time Delay Relay series
JSB-44MA using in the hard environmental condition
JSB-44MA Hybrid Time Delay Relay series JSB-44MA Hybrid Time Delay Relay series
Brief introductionJSB-44MA Hybrid Time Delay Relay series JSB-44MA Hybrid Time Delay Relay seriestop ↑
JSB-44MA Hybrid Time Delay Relay series JSB-44MA Hybrid Time Delay Relay series
DC OUTPUT:
1. Mechanical contact output.
2. 1 group conversion.
3. GJB1513-92.
JSB-44MA Hybrid Time Delay Relay series JSB-44MA Hybrid Time Delay Relay series
specificationJSB-44MA Hybrid Time Delay Relay series JSB-44MA Hybrid Time Delay Relay seriestop ↑
JSB-44MA Hybrid Time Delay Relay series JSB-44MA Hybrid Time Delay Relay series
No.
Item
Data
1
Operating Voltage
27VDC
2
             Over Load
1A×28VDC,100000
3
contact type
1 groups conversion
4
contact resistance
100mΩ
5
Dielectric Withstanding Voltage
500Vr.m.s.
6
      Insulation Resistance
500MΩ
7
Delay time
0~600s,600~1200s adjustable
(external potentiometer )
8
         Delay accuracy
±10%
9
Leakage rate
≤1Pa.cm3/s
10
Weight
70g
JSB-44MA Hybrid Time Delay Relay series JSB-44MA Hybrid Time Delay Relay series
how to orderJSB-44MA Hybrid Time Delay Relay series JSB-44MA Hybrid Time Delay Relay seriestop ↑
JSB-44MA Hybrid Time Delay Relay series JSB-44MA Hybrid Time Delay Relay series
JSB-44MA  /  027 –  0  2    /  0-600s
     1         2     3  4       5
1. Model
2. operating voltage.
3. mounting code
4. terminal arrangement code
5. Delay time
JSB-44MA Hybrid Time Delay Relay series JSB-44MA Hybrid Time Delay Relay series
Environmental ConditionJSB-44MA Hybrid Time Delay Relay series JSB-44MA Hybrid Time Delay Relay seriestop ↑
JSB-44MA Hybrid Time Delay Relay series JSB-44MA Hybrid Time Delay Relay series
No.
Item
Data
1
Temperature range
-55~ +85°C
2
Relative humidity
Normal 86-106kPa,low pressure4kPa
3
atmospheric pressure
98%(40°)
4
acceleration
245m/s2
5
Shock
10~2000Hz, 147m/s2
6
Vibration
490m/s2
JSB-44MA Hybrid Time Delay Relay series JSB-44MA Hybrid Time Delay Relay series